Appendix E: Using the ICP Flash Utility 105
Creating the Firmware Floppy Disks
Note: You will need at least two bootable MS-DOS floppy disks to complete this task.
You can’t create a bootable floppy disk using Windows 2000.
To create the firmware floppy disks:
1 Create a bootable MS–DOS floppy disk and copy these files to it:
IFU.exe
ICxxxx01.ufi
where xxx is the model number of your controller.
Note:
Most controller model numbers have a suffix (for example ICP9085LI). Check that the
.ufi file is the correct file for your controller before copying.
2
Copy each additional ICxxxx0x.ufi file to a separate floppy disk. (Some RAID controllers
have two UFI files; some have four. Each goes onto its own floppy disk.)
3 To use a menu-based IFU, see the following section.
To run the IFU from the command line, see page 106.
Running the Menu-based IFU
Note: You can also run the IFU from the command line (see page 106).
To run the menu-based IFU:
1 Shut down your operating system and reboot to DOS from a bootable MS-DOS floppy
disk or from a DOS partition on a bootable drive. (You can use a disk drive connected to
the controller you are updating.)
2 At the DOS command prompt, type
IFU
with no arguments.
The IFU’s main menu is displayed.
3 Select Select Controllers, then select the ICP RAID controller(s) to be flashed.
To update multiple RAID controllers in the same system, update the boot controller’s flash
first, restart the computer, then update the flash for the remaining controllers.
4 Select Select an Operation.
5 Choose the operation you want, then follow the on-screen instructions to complete the
task:
Update—Updates all the flash components on a RAID controller with the flash image
data from the UFI file.
Save—Reads the contents of a RAID controller’s flash components and saves the data
to a UFI file, which you can use to restore a RAID controller’s flash if required.
Ve r i f y Reads the contents of a RAID controller’s flash components and compares it
to the contents of the specified UFI file.
Ve r s i o n —Displays version information about a RAID controller’s flash components.
List—Lists all supported RAID controllers detected on your system.