30 FAQ’s for Actel’s Antifuse FPGA Programming
85. Does Actel recommend programming a commercial part before
programming an RH/RT part?
Ans. Before programming a RadHard or RadTolerant device, Actel recommends that you program a
commercially equivalent device to ensure the proper setup of the hardware and software. After you have
successfully programmed a commercial device, you can program your RH or RT device.
86. Where can I find the lot number and date code on Actel FPGAs?
Ans. To trace a device lot history from qualification test records, Actel must have the lot number of the
device under investigation. The lot number allows Actel to identify the silicon ingot and wafer from which
the device was fabricated.
For most Actel FPGAs, the lot number is printed on the bottom of the package and the date code is on
the top, although there are exceptions. In either case, the lot number is easy to identify given the following
example:
Lot Number: 2ACT312381
Date Code: 9919
The date code indicates that the device is fabricated in the 19
th
week of 1999, and the wafer is from lot
number 2ACT312381.
87. Are the electrical characteristics of the device guaranteed after
programming? Is it necessary to perform functional tests on the
programmed units?
Ans. The electrical characteristics outlined in the Actel device datasheet are guaranteed for all devices
that pass programming provided proper electro static discharge (ESD) and device handling procedures
are followed. Additionally, correct functional behavior is guaranteed for all devices that pass
programming.
88. Can I program the antifuse devices on board?
Ans. No, Actel neither recommends, nor supports this.
89. Is it possible to program antifuse devices in automatic testing
equipment?
Ans. No, you can only program Actel’s antifuse devices using Silicon Sculptor II or 3 and equivalent BP
programmers.
Refer to the Certified Programming Solutions section of the Programming Antifuse Devices Application
Note (www.actel.com/documents/AntifuseProgram_AN.pdf).