Adaptec RS Series Betriebsanweisung Seite 28

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 51
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 27
3-4
Cabling and Configuration
Setting Dual VEM Enable/Disable
This switch enables Dual VEM to be Enabled or Disabled for a shelf. In a single
shelf configuration the Dual VEM Enable/Disable switch must be set to Disabled.
In a dual shelf (daisy-chained) configuration the Dual VEM Enable/Disable
switch must be set to Enabled. The switch is located at the rear of the shelf (see
Figure 3-3). To set shelf to Enabled the switch should be set to 2. To set the
shelf to Disabled the switch should be set to 0 or 1.
Figure 3-3. Dual VEM Enable/Disable Switch Location
Mute
Temp
SCSI Out
SCSI In
LV D
SE
PSU 2
0
1
PSU 2
PSU 1
Dual VEM Enable/Disable
VEM
Host
Shelf
2 0/1 12
12
Seitenansicht 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 50 51

Kommentare zu diesen Handbüchern

Keine Kommentare