Removing and Installing Components
Advanced Cooling Module (ACM) Removal and Installation
The RAIDStation7 Ultra160 SCSI Storage Array is supplied with three ACMs
mounted on the rear of each shelf. The ACMs are removable and hot swappable.
The air flow created by the ACMs is from front to rear.
WARNING: Once you have removed an ACM from a Storage Array you
must block the resulting hole within 3 minutes. The hole may be blocked by
installing a new ACM or by replacing the failed ACM until a replacement is
obtained. Failure to do so can seriously disrupt air flow and cooling.
Removing an Advanced Cooling Module (ACM)
1. Remove the rear panel.
2. Loosen the captive thumbscrew that secures the ACM to the Storage Array.
3. Grasping the ACM handle pull the ACM assembly out of the Storage Array.
Installing an Advanced Cooling Module (ACM)
1. Hold the ACM assembly at 90 degrees to the shelf.
2. Insert the ACM into the empty ACM slot.
3. Align the two thumbscrews on the ACM with the threaded holes on the
shelf.
4. Tighten the thumbscrews.