Figure 2-2. ICP RAID Controller Layout GDT8586RZ
2.1.2 Installing the ICP RAID Controller
1. Power-off the computer system.
2. Disconnect power cord(s) and remove the system cover.
3. Install the ICP RAID controller into an available PCI slot. See Figure 2-3.
Note:
Use the appropriate bracket on the controller for your server platform.
4. Using SATA cables, connect the SATA drives to the internal SATA connectors located
on the ICP RAID Controller.
5. Replace the system cover and reconnect power cord(s).
Warning:
Attention the controller CPU can get HOT! Controller requires constant airflow for
cooling (min 1m/sec).
LED Connectors for:
- SUM Activity
- Activity Port A0
- Activity Port A1
- Activity Port B0
- Activity Port B1
- External Alarm
FRU Jumper
Right = Normal Mode
Left = Recovery Mode
PCI bus speed
Up = Auto (33/66MHz)
Low = Force 33MHz
Do not use connectors that are
not mentioned
LEDs on Reverse Side:
S = On in Recovery Mode
T = Internal Data Transfer
Sum = Activity on any Port
P66 = 66MHz PCI Clock
3V3 = 3.3 Volt available
5V = 5 Volt available
Per Port
Data= Activity per Port
Stat = Disk failed (if Auto Hot
Plug / Non-Int. Encl.
configured)
red
green
yellow
green
green
green
yellow
red
S T Sun P66 3V3 5V Data Stat
I²C Connectors for
SAFTE Backplanes
LED Connectors for:
- SUM Activity
- Activity Port C0
- Activity Port C1
- Activity Port D0
- Activity Port D1
- External Alarm
A0
A1
B0
B1
C0
C1
D0
D1