Adaptec RAID 2810SA Betriebsanweisung Seite 1

Stöbern Sie online oder laden Sie Betriebsanweisung nach Netzwerkverwaltungssoftware Adaptec RAID 2810SA herunter. Adaptec RAID 2810SA User`s guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 153
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - INSTALLATION AND USER’S GUIDE

INSTALLATION AND USER’S GUIDEADAPTEC SERIAL ATA RAID 2810SA

Seite 2 - Installation and User’s Guide

ixContentsWindows 3-3Installing the Driver in a New System 3-3Adding the Driver to an Existing System 3-4Linux 3-5Installing the Driver in a New Red H

Seite 3 - Disclaimer

B-35DOS UtilitiesThe following sample script file is a sample RAID.ACU script as referred to in the previous ACU command. This script creates the foll

Seite 4 - Adaptec Customer Support

C-1CCommand Line Interface (CLI) In this Appendix...IntroductionThis Command Line Interface (CLI) enables you to configure and manage controller compo

Seite 5

C-2Command Line Interface (CLI)CLI commands enable you to automate testing or array creation in a production environment using Windows command scripts

Seite 6

C-3Command Line Interface (CLI)Accessing the CLI in WindowsTo access the CLI:Note: The following procedure assumes that you accepted the default locat

Seite 7

C-4Command Line Interface (CLI)Displaying Information about Your DisksBefore creating any array, use the disk show space command to display informatio

Seite 8 - Canadian Compliance Statement

C-5Command Line Interface (CLI)Creating a RAID 0When creating a RAID 0, you need to determine the stripe size that is most suitable for your environme

Seite 9

C-6Command Line Interface (CLI)The stripe size can be 16, 32, or 64 KB. The default stripe size is 64 KB. Note that you can use the container reconfig

Seite 10 - Contents

C-7Command Line Interface (CLI)Alternatively, you can use the automatic failover commands that enable you to remove a failed drive and add a hot spare

Seite 11 - B DOS Utilities

C-8Command Line Interface (CLI)Displaying Controller InformationControllers exhibit a number of attributes that you can display or manage using the fo

Seite 12 - Glossary

C-9Command Line Interface (CLI)Example of controller details:AAC0> controller detailsExecuting: controller details Controller Information----------

Seite 13 - Introduction

xContentsB DOS Utilities Using the Adaptec Flash Utility (AFU) B-1Overview of the AFU B-2System Requirements B-2Firmware Floppy Disk Kit B-3Running th

Seite 14 - System Requirements

C-10Command Line Interface (CLI)Displaying Disk InformationThe CLI enables you to monitor or manage disk attributes, prepare a disk for use by a contr

Seite 15 - Kit Contents

C-11Command Line Interface (CLI)Example of disk show defects:AAC0> disk show defects /full=true (0,1,0)Executing: disk show defects /full=TRUE (CHA

Seite 16 - Adaptec 2810SA Controller

C-12Command Line Interface (CLI)Example of container list:AAC0> container listExecuting: container listTotal Oth Stripe Scsi PartitionLabel Type Si

Seite 17 - About the Documentation

C-13Command Line Interface (CLI) container show cache Example of container show cache:AAC0> container show cache 0Executing: container show cache 0

Seite 18 - Controller Features

C-14Command Line Interface (CLI)CLI Command DictionaryThis section contains a command reference.General Control Commandsclose Closes the currently ope

Seite 19 - Hot Spares

C-15Command Line Interface (CLI)open [/readonly={boolean}] [/domain={string}] {string} Opens a controller for access by the CLI. The controller must b

Seite 20 - Automatic Failover

C-16Command Line Interface (CLI)Switches/always—Specifies whether to clear the array even if it has data on it. The default is FAL SE , meaning that t

Seite 21

C-17Command Line Interface (CLI)Switches/io_delay—Number of milliseconds between each I/O used for the RAID 1 create./wait— If FAL SE (the default),

Seite 22 - Safety Information

C-18Command Line Interface (CLI)container create raid5 [/cache={boolean}][/stripe_size={integer}] [/clear={boolean}] [/label={string}] [</quick_ini

Seite 23

C-19Command Line Interface (CLI)Switches/cache—Specifies whether to enable caching on the array./stripe_size—Stripe size for the RAID 0. The default i

Seite 24 - Installing the Controller

xiContentsCLI Command Dictionary C-14General Control Commands C-14Container (Array) Commands C-15Controller Commands C-24Disk Commands C-27Logfile Com

Seite 25

C-20Command Line Interface (CLI)Parameters{container}—ID of the array containing information to display.Switches/all—Specifies whether to list all con

Seite 26

C-21Command Line Interface (CLI)container reconfigure [/stripe_size={integer}] [/mirror={boolean}] [/partition_move={boolean}] [/partition_size={integ

Seite 27 - Installing the Driver

C-22Command Line Interface (CLI)container remove global_failover {device_ID} [{device_ID}...] Removes a global failover assignment.Parameters{device_I

Seite 28 - Creating the Driver Disk

C-23Command Line Interface (CLI)Switches/read_cache_enable—Specifies whether to enable the read-ahead cache./unprotected—Specifies whether to set the

Seite 29

C-24Command Line Interface (CLI)container set label {container} {string} Assigns a new label to the array.Parameters{container}—ID of the array to whi

Seite 30

C-25Command Line Interface (CLI)controller firmware compare [/C{controller}] [{controller}...] [/D{UFI_file_path}] Compares the contents of each of th

Seite 31

C-26Command Line Interface (CLI)Switches/domain (Windows only)—Specifies the domain in which the host to be searched resides.controller pause_io [{int

Seite 32

C-27Command Line Interface (CLI)controller set container_verify [/verify_enabled={boolean}] Turns the container verify task on or off.Switches/verify_

Seite 33

C-28Command Line Interface (CLI)disk initialize [/always={boolean}] [/unconditional={boolean}] {device_ID} Initializes a disk on the currently opened

Seite 34 - Manager – Browser Edition

C-29Command Line Interface (CLI)disk set smart [/all={boolean}] [/clear={boolean}][/enable_exceptions={boolean}][/logerr={boolean}] [/perf={boolean}]

Seite 35 - Supported Browsers

1-11IntroductionIn this Chapter...Read this FirstRead this chapter before you begin installing your new Adaptec Serial ATA RAID 2810SA controller. Thi

Seite 36 - Remote and Managed Systems

C-30Command Line Interface (CLI)disk show partition Displays a list of partitions on the disks attached to the currently opened controller.disk show s

Seite 37 - Autorun

C-31Command Line Interface (CLI)Switches/repair—If FALSE (the default), the command only reports failures. If TRUE, bad blocks are automatically repai

Seite 38

C-32Command Line Interface (CLI)Task CommandsUse the CLI commands to display and manage tasks. A task is an operation that occurs only on the controll

Seite 39

C-33Command Line Interface (CLI)Enclosure CommandsThe enclosure commands operate on enclosure management devices that support Version 1.0 of the SAF-T

Seite 40

C-34Command Line Interface (CLI)enclosure prepare slot {enclosure} {slot} Prepares a device in a slot for insertion/removal.Parameters{enclosure}—ID a

Seite 41

C-35Command Line Interface (CLI)enclosure set power [/off{=boolean}] {enclosure} {powersupply} Turns on or off a specific power supply.Parameters{encl

Seite 42

C-36Command Line Interface (CLI)enclosure show power [{enclosure}] [{powersupply}] Displays the status of one or more power supplies.Parameters{enclos

Seite 43 - Browser Edition

C-37Command Line Interface (CLI)Using Automated Command ScriptsTo execute a CLI command script, type the at sign (@) followed by the file name that co

Seite 44 - Overview

D-1DSupported RAID TypesRAID is an acronym for Redundant Array of Independent Disks. The goal of RAID is to provide better performance and reliability

Seite 45 - Architecture Overview

D-2Supported RAID TypesRAID 0A RAID 0 is created by striping data across two or more disk drives. This striping scheme creates no redundancy to protec

Seite 46 - Logging In

1-2IntroductionSystem RequirementsThe following system requirements are presented: Operating system compatibility Storage requirements for drivers a

Seite 47

D-3Supported RAID TypesRAID 5This RAID type requires at least three drives. Like RAID 0, data is striped across the drives. However, in RAID 5, parity

Seite 48 - Registering Your Software

D-4Supported RAID TypesRAID 10This dual-level RAID type is created by using two or more equal-sized RAID 1 arrays to create a RAID 0. Both read and wr

Seite 49 - The Basics

E-1ESpecificationsDC Power RequirementsCurrent RequirementsEnvironmental SpecificationsNote: Forced airflow is recommended, but not required.Volt ag e

Seite 50 - Physical Devices

Glossary-1GlossaryAactivitySee task. ACUArray Configuration Utility. An application used to create, configure, and manage arrays from the controller’s

Seite 51 - ■ Capacity of the drive

Glossary-2GlossaryBbad segmentSegment that is in an unknown state.background consistency checkConsistency check performed as a background process. See

Seite 52 - Logical Devices

Glossary-3GlossaryclearForeground initialization of a fault-tolerant array. A clear operation zeros all blocks of the array. The array is not accessib

Seite 53

Glossary-4Glossarydrive LEDDisk indicator LED that illuminates during read or write operations.eventNotification or alert from the system, indicating

Seite 54 - Configuration Utility

Glossary-5Glossaryfree space/segmentSee available space/segment.Hhard disk, hard driveBasic unit of nonvolatile, nonremovable, magnetic storage media.

Seite 55 - Managing Arrays

Glossary-6GlossaryLlegacy diskDisk that contained a valid partition table when connected to the controller. The controller manages the disk as a legac

Seite 56

Glossary-7GlossaryPpartitionSee segment.phantom objectObject that represents a component that cannot be configured by the controller management softwa

Seite 57

1-3IntroductionKit ContentsYour Adaptec controller kit includes: Adaptec 2810SA controller (shown below) Adaptec Serial ATA RAID 2810SA Quick Instal

Seite 58

Glossary-8Glossarydrive. The controller generates parity every time data is written to the array, and it is distributed in stripes across all the driv

Seite 59 - Creating Arrays

Glossary-9GlossarySerial ATA (SATA)A successor to ATA that uses a serial, instead of parallel, interface. simple volumeA volume made up of disk space

Seite 60

Glossary-10GlossaryVverifySee consistency check command.volumeSee simple volume, spanned volume.

Seite 61 - Initializing Disk Drives

RAdaptec, Inc.691 South Milpitas BoulevardMilpitas, CA 95035 USA©2003 Adaptec, Inc.All rights reserved. Adaptec and the Adaptec logo are trademarks of

Seite 62 - Using SATASelect

1-4IntroductionAdaptec 2810SA ControllerThe Adaptec 2810SA controller is shown below. Note the position of the Serial ATA interface connectors necessa

Seite 63

1-5IntroductionAbout the DocumentationThe documentation set for this kit includes: Adaptec Serial ATA RAID 2810SA Quick Installation Guide—This print

Seite 64 - Viewing the Event Log

1-6IntroductionController FeaturesThe Adaptec 2810SA controller supports eight Serial ATA drives. The controller offers the features and performance i

Seite 65

1-7Introduction Online RAID Level Migration—Lets you change RAID levels without rebuilding your array from scratch. Multiple Arrays—Create multiple ar

Seite 66

RAdaptec Serial ATA RAID 2810SAInstallation and User’s Guide

Seite 67 - (for example

1-8IntroductionThe Adaptec 2810SA controller supports two types of hot spares: Global—Protects every array that the drive has enough available capaci

Seite 68 - Firmware Floppy Disk Kit

1-9IntroductionStorage Management Software OverviewThe Adaptec 2810SA controller includes the following software tools to manage your storage subsyste

Seite 69 - AFU followed

1-10IntroductionSafety InformationTo ensure you personal safety, as well as the safety of you equipment: Keep your work area and the computer clean an

Seite 70

1-11Introduction Avoid touching the controller against your clothing. The wrist strap protects components from ESD voltages present on the body only.

Seite 71

2-12Installing the ControllerIn this Chapter...OverviewTo install the controller and drives, install of each of the following: Serial ATA hard disk d

Seite 72 - AFU Commands

2-2Installing the ControllerInstalling the ControllerTo install the controller in the system cabinet:1 Shut down your computer and disconnect the powe

Seite 73 - Examples

2-3Installing the ControllerChecking Your Controller and DevicesNow that you have installed your Adaptec 2810SA controller and connected your Serial A

Seite 74

3-13Installing the DriverIn this Chapter...This chapter presents several scenarios for installing the controller driver. The scenarios depend on the f

Seite 75 - AFU Error Handling

3-2Installing the DriverCreating the Driver DiskInstalling a driver is easier if you create a driver disk. To create the driver disk:1 Set your system

Seite 76

3-3Installing the DriverWindowsThe following sections describe procedures for installing the controller with Windows 2000, Windows XP, or Windows Serv

Seite 77 - Creating an Array with ACU

iiCopyright©2003 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any

Seite 78

3-4Installing the DriverAdding the Driver to an Existing SystemIn this scenario, you are adding the driver to an existing Windows system. To install t

Seite 79

3-5Installing the DriverLinuxThe controller supports Red Hat and SuSE Linux versions as described in the table below. Notes If you do not find your k

Seite 80

3-6Installing the Driver6 When prompted, insert the driver disk and then select OK.7 Finish the installation procedures as appropriate for your operat

Seite 81

3-7Installing the DriverAdding the Driver to an Existing SystemThese driver installation instructions apply to both Red Hat and SuSE Linux systems. To

Seite 82

4-14Installing Adaptec Storage Manager – Browser EditionIn this Chapter...OverviewThis chapter discusses the installation procedure for installing Ada

Seite 83 - Using the Scripting Features

4-2Installing Adaptec Storage Manager – Browser EditionSupported BrowsersTo run Adaptec Storage Manager – Browser Edition, your computer must have a W

Seite 84

4-3Installing Adaptec Storage Manager – Browser EditionRemote and Managed SystemsThe illustration below shows a typical configuration of a single remo

Seite 85

4-4Installing Adaptec Storage Manager – Browser EditionInstalling Adaptec Storage Manager on WindowsNote: When installing on a FAT 32 file system, the

Seite 86

4-5Installing Adaptec Storage Manager – Browser Edition11 When prompted to restart your computer, accept the default (Ye s) and click Finish.12 The sy

Seite 87

4-6Installing Adaptec Storage Manager – Browser EditionConfiguring Internet Explorer for Local ManagementWhen using the High security setting, you mus

Seite 88

iiiAdaptec Customer SupportIf you have questions about installing or using your Adaptec product, check this document first—you will find answers to mo

Seite 89 - Script File Syntax

4-7Installing Adaptec Storage Manager – Browser EditionConfiguring Internet Explorer for Remote ManagementIf you know the IP address of the managed sy

Seite 90

4-8Installing Adaptec Storage Manager – Browser EditionInstalling Adaptec Storage Manager on LinuxNote: When performing this installation, keep in min

Seite 91

4-9Installing Adaptec Storage Manager – Browser Edition9 Click OK.The Shell window you used to launch the installation indicates that some daemons are

Seite 92

5-15Using Adaptec Storage Manager – Browser EditionIn this Chapter...Overview 5-2Architecture Overview 5-3Logging In 5-4Installing a Security Certific

Seite 93

5-2Using Adaptec Storage Manager – Browser EditionOverviewThis chapter describes how to use Adaptec Storage Manager – Browser Edition to manage arrays

Seite 94 - ■ No—Disable read caching

5-3Using Adaptec Storage Manager – Browser EditionArchitecture OverviewA locally managed system requires all of the following components: A supported

Seite 95

5-4Using Adaptec Storage Manager – Browser EditionLogging InTo login:1 Start Adaptec Storage Manager – Browser Edition. In Windows, click Start >

Seite 96

5-5Using Adaptec Storage Manager – Browser EditionTo log in from any system with a Web browser:1 Start the Web browser application and type the IP add

Seite 97 - Error Handling

5-6Using Adaptec Storage Manager – Browser EditionInstalling a Security CertificateIf you chose not to install a security certificate when you install

Seite 98

5-7Using Adaptec Storage Manager – Browser EditionThe BasicsAn example of a typical Adaptec Storage Manager – Browser Edition screen is shown below.

Seite 99 - Playback and Record Notes

ivEurope Visit our Web site at www.adaptec-europe.com. German: To speak with a Technical Support Specialist, call +49 89 43 66 55 22, Monday to Frid

Seite 100 - DOS Utilities

5-8Using Adaptec Storage Manager – Browser EditionImmediately following the header frame is a controller information line including the model number o

Seite 101 - Command Line Interface

5-9Using Adaptec Storage Manager – Browser EditionChanging How Drives are DisplayedBy default, the Physical Devices displays a condensed view of the c

Seite 102 - Accessing the CLI

5-10Using Adaptec Storage Manager – Browser EditionAny part of a drive used in an array is shown as a gray segment within the bar. Selecting any gray

Seite 103 - Using the CLI

5-11Using Adaptec Storage Manager – Browser EditionThe main area of the Logical Devices view is used to display the arrays on this controller. It defa

Seite 104 - Command Line Interface (CLI)

A-1AAdaptec RAID Configuration UtilityIn this Appendix...The Adaptec RAID Configuration (ARC) utility is an embedded BIOS utility that includes: Array

Seite 105

A-2Adaptec RAID Configuration UtilityThe Adaptec RAID Controller menu appears, presenting the following options: Array Configuration Utility SATASel

Seite 106

A-3Adaptec RAID Configuration UtilityViewing Array PropertiesTo view the properties of an existing array:1 At the BIOS prompt, press Ctrl+A.2 From the

Seite 107

A-4Adaptec RAID Configuration UtilityNotes If the controller is not a boot device, you can disable its runtime BIOS, see page A-10. When the BIOS is

Seite 108

A-5Adaptec RAID Configuration Utility6 Select Yes to delete the array or No to return to the previous menu. At the Array Properties dialog box, select

Seite 109

A-6Adaptec RAID Configuration UtilityCreating ArraysBefore creating arrays, make sure the disks for the array are connected and installed in your syst

Seite 110 - Displaying Disk Information

vLimited 3-Year Hardware Warranty1. Adaptec, Inc. (“Adaptec”) warrants to the purchaser of this product that it will be free from defects in material

Seite 111 - Displaying Array Information

A-7Adaptec RAID Configuration UtilityAssigning Array PropertiesThe ACU can be used to assign array properties only prior to array creation. (After the

Seite 112 - Example of

A-8Adaptec RAID Configuration Utility6Specify whether you want to enable write caching for the array. When you are finished, select Done.Initializing

Seite 113

A-9Adaptec RAID Configuration UtilityRescanning Disk DrivesTo rescan the drives connected to the controller:1 At the BIOS prompt, press Ctrl+A.2 From

Seite 114 - CLI Command Dictionary

A-10Adaptec RAID Configuration Utility Controller Configuration Options: Drives Write Cache (Default: Drive's Default)—When Enabled, write cach

Seite 115 - Container (Array) Commands

A-11Adaptec RAID Configuration Utilitydisplayed during system POST. Displaying the devices adds a few seconds to the overall POST time.4To exit SATASe

Seite 116

A-12Adaptec RAID Configuration UtilityTo access the event log:1 When you turn on or restart your system, press Ctrl+A to access the ARC when prompted

Seite 117

B-1BDOS UtilitiesIn this Appendix...Using the Adaptec Flash Utility (AFU)The Adaptec® Flash Utility (AFU) is a DOS application used to update the flas

Seite 118 - Switches

B-2DOS UtilitiesThe process of updating a controller’s flash must be done carefully to avoid rendering the controller inoperable. AFU is designed to b

Seite 119

B-3DOS Utilities The AFU can run from a partition on a drive or array attached to the controller you are updating. Once the flash update begins, no I

Seite 120

B-4DOS UtilitiesRunning the AFUYou can run the AFU from its graphical user interface (GUI) or from the command line. Accessing the AFU from the GUITo

Seite 121

viRegulatory Compliance StatementsFederal Communications Commission Radio Frequency Interference StatementWARNING: Changes or modifications to this un

Seite 122

B-5DOS UtilitiesThe AFU switches are as follows /C <Controller ID> is one or more controller IDs representing the set of controllers on which to

Seite 123

B-6DOS Utilities5 At the DOS prompt, type afu list and press Enter.This command displays a list of the controllers in your system. Take note of the co

Seite 124 - Controller Commands

B-7DOS Utilities9 If there are additional UFI files this process is repeated until the complete image has been read, the controller flash is updated w

Seite 125

B-8DOS UtilitiesSAVEThe SAVE command saves the contents of a controller’s flash in a UFI file. The name of the UFI file is based on the controller typ

Seite 126

B-9DOS UtilitiesExampleA:\> AFU UPDATE /C 0Adaptec Flash Utility V4.0-0 B5749(c)Adaptec Inc. 1999–2002. All Rights Reserved.Updating Controller 0 (

Seite 127 - Disk Commands

B-10DOS UtilitiesAfter using the VERSION command, you must restart the computer upon completion of this command. Default Switch ValuesIf you do not in

Seite 128

B-11DOS UtilitiesUsing the Array Configuration Utility (ACU)Adaptec RAID Configuration (ARC) is a embedded BIOS utility that includes: SATASelect—Use

Seite 129

B-12DOS UtilitiesRunning the ACUTo run the ACU for MS-DOS:1 Browse to Dos\Apps\Acu on the Adaptec installation CD.2 Copy acu.exe onto a bootable MS-DO

Seite 130

B-13DOS UtilitiesSelecting Segments for New ArraysTo select one or more segments to assign as members of the new array:1 Use the arrow keys to select

Seite 131 - Logfile Commands

B-14DOS Utilities2 Type in an optional label for the array and press Enter.3 Enter the desired array size. The maximum array size available based on t

Seite 132 - Task Commands

viiCanadian Compliance StatementThis Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.Cet a

Seite 133 - Enclosure Commands

B-15DOS UtilitiesManaging ArraysThe Manage Arrays option enables you to perform the following functions: Viewing Array Properties Assigning Hot Spar

Seite 134

B-16DOS Utilities3Select a drive and press the Insert key to assign the drive as a spare. The specified drive is displayed in the Assigned Hotspares D

Seite 135

B-17DOS UtilitiesTo initialize a drive:1 Select Initialize Drives from the Main menu.2 Use the arrow keys to select a channel.3 Select the disks you w

Seite 136

B-18DOS UtilitiesDeleting ArraysCaution: Back up the data on an array before you delete it. All data on the array is lost when you delete the array, a

Seite 137 - CLI command script:

B-19DOS UtilitiesThe table below lists the required and optional ACU command-line switches. Switch Description/P <file>Playback Mode Switch—In t

Seite 138 - Supported RAID Types

B-20DOS UtilitiesPlayback ModePlayback mode enables you to create one or more arrays based on the properties defined in a script file. It also enables

Seite 139

B-21DOS UtilitiesIn addition, there are other array properties that enable you to control the various array settings during creation. See Array Defini

Seite 140

B-22DOS UtilitiesBecause the ACU reads the entire script file before creating any arrays, the position of the InitializeAll=Yes property within the sc

Seite 141 - Spanned Volume

B-23DOS UtilitiesThe ACU provides a way to do this. When you use record mode to record a controller’s configuration and you specify a log file (/L swi

Seite 142 - Specifications

B-24DOS UtilitiesBuild/Verify Operations on RAID 10 ArraysFor a RAID 10 array, the status message indicates the percent of the build/verify completed

Seite 143

viiiContents1 Introduction Read this First 1-1System Requirements 1-2Operating System Compatibility 1-2Storage Requirements 1-2Motherboard Compatibili

Seite 144 - Glossary-2

B-25DOS UtilitiesArray Definition Block PropertiesThe table below lists the properties that can be specified within an array definition block. The tab

Seite 145 - Glossary-3

B-26DOS UtilitiesThe following sections describe each of these keywords in detail.Array Keyword Array is a required keyword, indicating the start of a

Seite 146 - Glossary-4

B-27DOS UtilitiesType KeywordType is a required keyword, indicating the array type. There is no default value. Note: For information about the maximum

Seite 147 - Glossary-5

B-28DOS UtilitiesNotes When assigning spare drives to a RAID 10 array, the ACU assigns all the drives in the list to all the arrays within the multil

Seite 148 - Glossary-6

B-29DOS UtilitiesExamplesInitializeAll=YesInitializeAll=NoMethod KeywordMethod is an optional keyword, indicating which method to use when creating a

Seite 149 - Glossary-7

B-30DOS UtilitiesSize KeywordThe Size keyword specifies the size of the array. Specify the size as an integer or a decimal number, followed by the uni

Seite 150 - Glossary-8

B-31DOS UtilitiesWait Keyword The Wait keyword indicates whether the ACU should wait for the new array’s build/verify or clear to complete before cont

Seite 151 - Glossary-9

B-32DOS UtilitiesError HandlingBecause the ACU scripting feature is designed to run without user interaction, the ACU handles errors during record and

Seite 152 - Glossary-10

B-33DOS Utilities9 Specified array size too big—You specified an array size that is larger than the maximum size allowed for this array.10 Number of d

Seite 153 - Milpitas, CA 95035 USA

B-34DOS UtilitiesPlayback and Record NotesWhen using ACU in playback or record mode, note the following: When recording an array, the ACU does not cr

Kommentare zu diesen Handbüchern

Keine Kommentare