3. Click OK to clear the conguration; click Cancel to close the window without clearing the conguration.
Changing the Agent Base Port Setting
You can change the base port setting for the maxView Storage Manager Agent, if needed, to
accommodate changes in your network or IT requirements. The Agent can use any open port for
communication. The default port is 34571. If you change the port, you must restart the maxView Storage
Manager Agent for the change to take effect.
To change the Agent base port setting:
1. In the Enterprise View, select a system.
2. On the ribbon, in the System group, click System Settings.
The Agent Settings window opens. In the gure below, the base port setting is circled in blue.
3. Enter the new base port, then click OK.
4. Restart the Agent.
109Proprietary and Condential to PMC-Sierra, Inc.
Document No.: CDP-00278-02-A Rev. A, Issue: