Adaptec 2100S - SCSI RAID Controller Betriebsanweisung Seite 110

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 135
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 109
4-2
RAIDUTIL Command Line Utility
Exit Status
RAIDUTIL exits with either of the following error status indications:
Device Address Syntax
When you use RAIDUTIL to specify a device or group of devices,
use an address of the form dDbBtTdD, where
To list all devices on a particular bus, specify only dDbB. To list all
devices on a controller, specify only dD. To display device
information, use the List
(-L) command. Always separate drive
addresses with a comma.
0 Error-free termination
1 Error termination (the message log contains the error
information)
D
Controller ID.
B
Controller channel (or bus) number of the bus to which
the disks are attached. The range is 0 – 7.
T
Always 0.
D
the second “D”—Always zero.