Arrays may not be displayed correctly, even after you restart
your computer.
To resolve the problem:
As root, run 'resmgr -r -m vtoc' until it fails. Then, as
root, run '/etc/conf/bin/idconfupdate -f'. Then, reboot.
4.11 SAS and SATA controllers and Adaptec 335SAS enclosure
When the Adaptec 335SAS enclosure is attached to an ICP
SAS controller, such as ICP9085LI or ICP5085BR, the
enclosure numbering nomenclature starts with "0". For
example, if two Adaptec 335SAS enclosures are connected to an
ICP9085LI SAS controller, management tools such as Storage
Manager will denote the enclosures as "Enclosure 0" and
"Enclosure 1". When the Adaptec 335SAS enclosure is attached
to an Adaptec SATA controller, such as ICP9047MA or
ICP9087MA, the enclosure numbering nomenclature starts with
"14". For example, if two Adaptec 335SAS enclosures are
connected to an ICP9087MA controller, management tools such
as Storage Manager will denote the enclosures as
"Enclosure 14" and "Enclosure 15".
4.12 Using the ICP5085BR in a Gateway 920
When more than one ICP5085BR controllers are installed in a
Gateway 920 server, the system will not POST.
4.13 Creating an Array from the ICP Storage Manager CD
When you create an array with the ICP Storage Manager
bootable CD, the maximum size of the array is 2 TB.
4.14 Using the controller with an Adaptec S50 JBOD Enclosure
Temperature warnings from Adaptec S50 JBOD Enclosure (firmware
version T016) are not shown in Adaptec Storage Manager (or on
the enclosure).
4.15 SMART errors on SATA controllers
During POST, SMART errors for disk drives connected to SATA
controllers are indicated as follows:
o N = No SMART errors reported
o Y = SMART errors reported
o N/A = Disk drive does not support SMART error reports
4.16 Firmware upgrades
Check your controller BIOS settings after upgrading the
controller firmware/BIOS, as the BIOS may have been reset to
its default settings during the upgrade.
4.17 RAID 10/50/60 array leg limitations
Kommentare zu diesen Handbüchern