Adaptec SCSI RAID 2120S Installationsanleitung Seite 189

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 278
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 188
5-18
disk Commands
The items in the display are described as follows:
Number of PRIMARY defects on drive:
This item shows the details regarding any primary disk
defects. In the example, there are two defects.
Defect 1 at cylinder 12, head 5, sector 59
This item shows where defect 1 occurred. In the example, the
defect occurred on head 5 of cylinder 12 located in sector 59.
Defect 2 at cylinder 550, head 1, sector 44
This item shows where defect 2 occurred. In the example, the
defect occurred on head 1 of cylinder 550 located in sector 44.
The command shows any additional defects.
Number of GROWN defects on drive: 0
This item shows the list of grown defects (if any). In the
example, there are no grown defects, so the command
displays the value 0 (zero).