9-18
enclosure Commands
The following example sets the monitor reporting interval for
enclosure management devices 0 and 1 to 20 seconds:
AAC0>enclosure set interval 20
Executing: enclosure set interval 20
You may want to use the enclosure show status command
again to see the change in the power supply’s status, as in the
following example:
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
0 0:00:00 0 20 UNLOCKED OFF
.
.
.
Enclosure UpTime D:H:M PowerCycle Interval Door Alarm
--------- -------------- ---------- -------- -------- -------
1 0:00:00 0 20 UNLOCKED OFF
Related Commands
enclosure commands:
enclosure list (page 9-6)
enclosure show status (page 9-36)