Interpreting Status LEDs
DPU LED States when Starting as Standalone or Backup DPU
While the DPU is being restarted, the State Led moves through various color
cycles as it goes to a Standalone state or Redundant Configuration state with
or without a working backup DPU. Use the following table for an
understanding of the state transitions.
DPU STATES Active DPU State / LED
(Key Switch in Run Position)
Inactive DPU State / LED
(Key Switch in Run Position)
Standalone DPUs State = SA
LED = Solid Green
State = ASA
LED = Solid Yellow
Standalone DPUs Commanded to Go
Redundant
State = FSB
LED = Blinks Green to Black
State = EDB
LED = Blinks Red to black
Backup DPUs with Backup Warming Up State = WSB
LED = Blinks Green to Red
State = SBWU
LED = Blinks Yellow to Red
Backup DPUs with Backup as Hot Standby State = HSB
LED = Blinks Green to Yellow
State = SBH
LED = Blinks Yellow to Black
Backup DPUs with Failed Standby State = FSB
LED = Blinks Green to Black
State = Dead / Indeterminate since
Failed
IOM Health – RED
CP Health LED = Frozen
Backup DPUs with Failed Active State = Dead / Indeterminate since
Failed
IOM Health – RED
CP Health LED = Frozen
State = Transitions from SBH to FSB
and becomes Active DPU
LED = Blinks Green to Black
Backup DPUs Commanded to Go
Standalone
State = SA
LED = Solid Green
State = SBH to ASA
LED = Blink Red to Black (EDB)
then to Solid Yellow (ASA)
Key to abbreviations
SA = Standalone
ASA = Alternate Standalone
WSB = Warming Stand By
SBWU = Stand By Warming Up
HSB = Hot Stand By
SBH = Stand By Hot
EDB = Emptying DB
FSB = Failed Stand By
LED Indications during Shut Down and Restart
If the DPU is shut down by either a soft reset or removal of the 24VDC input
power, it will attempt to save its database in non-volatile memory (flash).
The CP LED will turn yellow to indicate this. When the database save has
finished, the CP LED will turn red. After the database has been saved, the
DPU will restart if it still has 24VDC input power. Otherwise, it will shut off.