Adaptec 2110S - SCSI RAID Controller Installationsanleitung Seite 102

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 106
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 101
D-2
Adaptec RAID Installation Guide
NVRAM Reset
Adaptec RAID controllers retain their setup parameters even when
powered off. These parameters are stored on the controller in an area
of nonvolatile memory (NVRAM). There is a possibility that,
through improper configuration, the controller can be put into a
state where it hangs the system during start. If this happens, the
parameters stored in the NVRAM can be restored to their default
settings by following these steps:
Note: The 2000S and 2005S controllers do not have an
NVRAM reset jumper. Use SMOR’s Default command or
RAIDUtil’s -X command to reset the NVRAM.
1 Power off the system.
2 Install a jumper on the NVRAM reset jumper connector. Refer
to Appendix A for the location of the jumper connector.
3 Power on the system and wait until the LEDs 3, 5, 7, and 8 on
the controller begin flashing.
4 Power off the system and remove the jumper.
5 Restart the system. If the system restarts normally, the
controller can now be configured using SMOR or Storage
Manager.
If the system fails to start, refer to Appendix C for additional
information.
Flash Mode 0
The Adaptec controller firmware, BIOS, and SMOR are all
upgradable. There is a possibility that an unsuccessful upgrade
could render the controller inoperable. If this happens, you need to
reset the controller firmware, BIOS, and SMOR. First, create a SMOR
start disk as follows:
1 If your system hangs with the Adaptec controller installed,
remove the controller from your system. Otherwise, leave the
controller installed and proceed to the next step.
COMBINED RAID IG.BOOK Page 2 Tuesday, September 25, 2001 5:46 PM