Appendix E Best Practices 89
Replacing an HBA On a SPARC System
Upon replacing an existing HBA card with a new card on a SPARC system, the new
card automatically detects the existing configuration upon installation and no further
action is required. However, if the new HBA is not seeing one or more volumes in the
existing configuration, rescan those volumes to enable their detection.
Replacing an HBA On an x64 System
Upon replacing an existing HBA card with a new card on an x64 system, the BIOS
RAID Configuration utility sends a warning message alerting you to a configuration
change during the initialization process of the new card. The existing drives and
volumes in the configuration will not be activated on the new card until you accept
the configuration change indicated in the warning message.
To activate the existing drives and volumes on the new card, do one of the following:
Upon receiving the configuration change warning message, press Enter to accept
the configuration change.
View the configuration change through the BIOS Configuration utility (press
Ctrl+A when prompted during POST), and accept the change from the utility.