Appendix E Best Practices 85
Pulling a Cable and Reconnecting It To the Same
Port
Wait at least two minutes between pulling a cable and reconnecting it to the same
port on an HBA or JBOD. To avoid confusing the controller, wait until the physical
drives are removed from the display of the GUI and CLI.
Connecting a JBOD With SATA Disks
When connecting a JBOD with SATA disks to an HBA, connection problems might
occur if the JBOD was previously connected to a different HBA. This is due to a SAS
feature called, affiliation. An affiliation is used by the SAS protocol to prevent
multiple SAS initiators (HBAs) from walking on each other when communicating
with SATA drives. To avoid these connection problems, remove the affiliation by
power cycling the JBOD prior to connecting the JBOD to the new HBA.
Best Practices For Cabling to Disk
Enclosures
The HBA supports using a single connection, or path, between a RAID card and a
JBOD. Therefore, when connecting a RAID card to a disk enclosure, be sure to use
only one cable. Using more than one cable does NOT provide redundancy.
Best Practices For Testing Hard Drive
Failure Conditions
When hot-plugging hard drives to test failure conditions, wait at least one minute
between removing the drive and re-inserting it. Waiting one minute gives the
controller time to recognize the removal of the hard drive. In a true failure situation,
a removed drive is replaced with a different hard drive. In testing situations where
the same drive is re-inserted, a one-minute waiting period before re-insertion is
required.