Troubleshooting the SIERRA™ plus film digitizer 70
VIDAR Film Digitizer Installation Guide
Symptom Corrective action
Multi-film feed tray won’t feed films. The multi-film feed tray must be connected to the
digitizer with the multi-film feed tray cable. The cable is
located above the digitizer body, on the left side (when
viewed from the front). Ensure the cable is present.
Ensure one end of the cable is plugged into the jack on
the multi-film feed tray, and the other end is plugged
into the digitizer. After checking cable and connections,
restart digitizer, then restart PC after LED turns green.
After applying power, LED on front
keeps flashing yellow.
After power is applied, digitizer normally requires about
3.5 minutes to normalize and calibrate, during which
time the LED will flash yellow. If LED flashes yellow for
more than 5 minutes, reset digitizer or turn power off
and on again (both procedures described later in this
chapter).
LED remains dark, in spite of using
proper power-on procedure described
later in this chapter.
1. Ensure wall outlet is providing AC power: obtain
another electrical device known to be working, and
plug it into that AC wall outlet.
If other device doesn’t work, AC power is not
available at that wall outlet. Get help from
building services.
If other device does work, AC power is available
from that outlet. Go to step 2.
2. With power applied to digitizer, look into digitizer film
entrance slot. If you see light coming from inside
digitizer, power is on. For this condition (LED dark,
internal light on), get qualified technical help.
3. If you have another SIERRA film digitizer, try its
power supply.
If digitizer works with other power supply, original
power supply is defective. Obtain replacement
VIDAR SIERRA
power supply from your system
integration specialist.
Do not substitute any
other power supply.
If digitizer does not work with other power supply,
digitizer is defective. Get qualified technical help.
continued